ELISA

Microplate ELISA Reader

Features

  • 7" TFT touch LCD screen
  • Test results simultaneous displayed in screen
  • LED light source with lifespan over 100,000 hours
  • Bichromatic, 8-channel optical system
  • Large storage capacity up to 200 test protocols and
  • 100,000 results
  • 3 shaking modes with variable time
  • Windows system, operation
  • Self-check, malfunction alarm

Application Tests

  • Remaining poison in food
  • Melamine
  • Hormone, such as T3, T4, TSH
  • Test Giant cell IgG antibody, Toxoplasm IgG antibody, Rubella IgM antibody,
  • Fever blister I-IgM antibody, Fever blister II-IgM antibody
  • Cancer marker, Typhoid fever, Paratyhoid fever
  • Sexually transmitted disease (such as gonorrhea, syphilis, HIV) & hepatitis (such
  • as hepatitis-A, hepatitis-B, hepatitis-C)
  • Fetal antibody & vaccinum reaction, etc
triturus
 grif
Microplate ELISA Washer

Specifications

Plate type

96-well plate

Washing head

8/12 type

Residual aspiration volume

< 2ul

Dispensing volume

10 ~ 3000ul, step by 1ul

No. of washing cycle

1 ~ 99 adjustable

Soak time

0 ~ 999s

Shaking time

0 ~ 999s

Temperature

5°C ~ 35°C

Humidity

15% ~ 85%

Power supply

AC 110V, 60Hz / AC 220V, 50Hz

Dimension (mm)

400(L) x 310(W) x 169(H)

Weight

8 kg

triturus
 grif
Triturus® (Fully automated Open system for ELISA)

Triturus® is a completely open and fully automated ELISA analyzer which can perform a variety of different tests on a group of samples and process several batches simultaneously.

What does Triturus® offer?
Triturus® offers complete automation of ELISA without changing the laboratory‘s normal workflow routine.

For which laboratories is Triturus® designed?
The flexibility of Triturus® ensures maximum performance in laboratories with a complex work load, involving a large number of samples and different groups of tests

Fully automated: Triturus® performs all the steps of any microplate ELISA assay including:

  • Sample dilution
  • Reagent dispensing
  • Washing
  • Reading
  • Calculation of results

Completely open Triturus® can be programmed for all the steps in any ELISA micro-well test.
Multi-test capability Triturus® : can perform up to 8 different tests per batch on a given sample or on a group of samples (e.g.:TORCH profile, EBV profile).
Multi-batch capability Triturus®: can independently schedule several consecutive groups of tests. New work batches can be loaded while other batches are being processed.
Computer interfacing Triturus®: allows a bi-directional host communication and on-line connection for data management and reporting.

Features of the Triturus® system:

  • High Speed Processing
  • Fixed Needles and/or disposable tips
  • High Capacity
  • Sample Identification and bar code reading
  • Multiple and/or serial sample dilution
  • Optimal Assay performance
triturus
 grif
HIV Kits
HIV 4th Gen Microwell ELISA

HIV kits from Vanguard, this can be used with our open source ELISA testing machine Triturus

Intended use Simultaneous detection of HIV p24 antigen and antibodies to Human Immunodeficiency Virus Type 1 (HIV-1) and Type 2 (HIV-2), in human serum or plasma.
Method Microwell ELISA
Capture antibody & antigens

Monoclonal antibody to HIV p24 antigen.

Recombinant proteins derived from the envelope proteins of HIV 1 and HIV 2.

Early detection of the p24 antigen

Reduced window period as the system can detect IgM antibodies to HIV 1 & HIV 2.

High sensitivity due to recombinant proteins

Reduced risk of false negative results.

Conjugate

Monoclonal anti-HIV p24 antibody conjugated with Biotin.

HIV antigens & Streptavidin labeled with HRPO

High affinity of the Streptavidin – Biotin system results in excellent specificity for the p24 antigen.

Double antigen sandwich system for antibodies to HIV1 & HIV 2 results in high sensitivity and specificity.

Substrate Ready to use TMB + H2O2

Convenience.

No chances of error or contamination.

Incubation Time 30 minutes + 15 minutes +            15 minutes  +  30 minutes Calibrated to achieve reliable and simultaneous detection of the antigen and antibodies to HIV 1 & HIV2.
 

 

HIV

 Make In Indiavd logo
HBsAg Microwell ELISA

HBsAg kits from Vanguard, this can be used with our open source ELISA testing machine Triturus

Intended use Qualitative determination of Hepatitis B surface Antigen in human serum or plasma.
Method Microwell ELISA
Capture antibody

Monoclonal antibody to HBsAg

Highly specific.

Reduced risk of false positive results.

Conjugate

Polyclonal antibody to HBsAg conjugated with HRPO.

Substrate Ready to use

TMB + H2O2

Convenience.

No chances of error or contamination.

Incubation Time 1 hour + 30 minutes

Calibrated to achieve high sensitivity.

Sensitivity 100% No False Negatives or False Positives in the 760 samples tested.
Specificity 100%
Analytical Sensitivity 0.4 PEIU/ml
 hbsag
 Make In Indiavd logo
HCV Microwell ELISA

HCV kits from Vanguard, this can be used with our open source ELISA testing machine Triturus

Intended use Qualitative determination of antibodies to Hepatitis C Virus in human serum or plasma.
Method Microwell ELISA
Capture antigen 

HCV specific recombinant proteins: core, NS3, NS4, NS5

High sensitivity due to recombinant proteins.

Reduced risk of false negative results.

Conjugate

Monoclonal anti human IgG conjugated with HRPO

Substrate Ready to use TMB + H2O2

Convenience.

No chances of error or contamination.

Incubation Time 30 minutes + 30 minutes + 30 minutes Calibrated to achieve high sensitivity.
Sensitivity 100% No False Negatives & low False Positives in the 625 samples tested.
Specificity Greater than 99.5%
hcv
 Make In Indiavd logo
Created for Span Healthcare Private Limited - One stop Solution for the Transfusion Medicine Fraternity.
 .